Caretex Gentuğ Textile

EVAC Patient Transfer Sheet

A heavy-duty Oxford-weave evacuation and transfer sheet, laboratory-tested for safe horizontal movement of non-ambulatory patients in hospitals, ambulances and care facilities.

250 kg Safe Working Load Flame-Retardant Antibacterial Reinforced Multi-Handle System ✓ Tested to 500 kg Static Load
EU MDRMedical Device Regulation
CE · MDClass I — Rule I
EN ISO 13485Quality Management
BS 7175Crib 5 Flammability

Fast, Safe Horizontal Patient Evacuation

The EVAC Patient Transfer Sheet is a finished aid for patient evacuation that helps trained personnel secure and move bedridden or mobility-impaired patients during an emergency evacuation. It is designed to be placed between the mattress and the bed and kept ready for use at all times.

During evacuation, integrated straps secure the patient in place, while reinforced handles and straps allow trained personnel to move them in a controlled way toward the designated safe area. Woven from a heavy-duty Oxford fabric (internally referenced as the Kodro weave) reinforced with PES handles and straps, the sheet is built for repeated hard use.

It can be sprayed and wiped down with hospital-grade disinfectant, or machine washed at temperatures up to 90°C, and is compatible with steam sterilization (autoclave) under validated conditions. Suited to hospitals, nursing homes, clinics and emergency-response environments.

EVAC Patient Transfer Sheet
Navy Blue200 g/m² Oxford WeavePES Handles & Straps250 kg SWL
Material Identification
Product Name
Navy Kodro Patient Evacuation Sheet
Composition
Heavy Oxford Weave + PES Handle/Strap
Colour
Navy Blue
Grammage
200 g/m² (±10%)
Safe Working Load
250 kg
Basic UDI-DI
8682550EVAC8W
Risk Class
Class I (EU MDR)
Washable
Up to 90°C

Made in Any Size, On Request

Specification
Detail
Sizes
Manufactured to any size on request — no fixed dimensions
Colour
Navy Blue
Grammage
200 g/m² (±10%) Oxford weave
Safe Working Load
250 kg

Not suitable for vertical lifting (crane/hoist) — designed for horizontal transfer and repositioning only.

Engineered for Emergency Evacuation

🔥

Flame-Retardant

Meets BS 7175:1989 Crib 5 ignition-source acceptance criteria and is rated B1 to DIN 4102-1.

🤝

Reinforced Multi-Handle System

Long end handles plus side handles allow secure multi-person lifting with a healthy caregiver posture.

🦠

Antibacterial

Meets antibacterial acceptance criteria in independent lab testing.

♨️

Autoclave Compatible

Suitable for steam sterilization (autoclave) under validated conditions.

📦

Foldable & Compact

Folds flat for storage between the mattress and bed base — ready for immediate deployment.

⚖️

250 kg Safe Working Load

Tested with a static load of 500 kg held for 10 minutes with no damage — a 2× safety margin over the rated SWL.

🧼

Cleanable & Disinfectable

Machine washable up to 90°C, or spray-and-wipe with hospital-grade disinfectant between patients.

❄️

Cold-Flex Resistant

Passed low-temperature bend testing at −20°C with no cracking, per DIN EN 1876-1 — reliable in ambulance and outdoor conditions.

EVAC Sheet in Use

Turn, Slide, Pull — Feet First

EVAC Sheet

Rapid single- or multi-person evacuation

The Evac Sheet stays folded between the mattress and the bed base at all times, ready for immediate use. In an urgent evacuation, one rescuer can move the patient to safety using the foot-end handle alone.

✓Grasp the handle at the foot of the bed and turn the mattress 90°
✓Slide the patient down onto the floor and pull toward the gathering point
✓Always pull feet-first, both on the floor and down stairs, to minimize injury risk

Cleaning, Disinfection & Drying

Care Instructions
Cleaning
Machine washable up to 90°C. Remove visible soiling with a damp cloth before first use and after each use.
Disinfection
Use approved surface disinfectants (alcohol- or quaternary-ammonium-based) and observe the recommended contact time, or spray and wipe with a hospital-grade disinfectant.
Drying
Air dry, or tumble dry at max 40°C, away from direct sunlight. Do not dry clean, bleach, or iron.
Sterilization
Compatible with steam sterilization (autoclave) under validated conditions.

Inspect after each cleaning for damage, tears, loose seams or damaged handles — do not use if any damage is found. Store clean and dry, protected from direct sunlight, between 0°C and +45°C; do not store under heavy objects.

Verified to Double the Rated Load

An independent load-capacity test held the sheet under a static test load for 10 minutes with no fabric damage, no seam damage, no handle or strap damage, no permanent deformation, and a passed function check — confirming the sheet’s rated Safe Working Load with a 2× safety margin.

250 kgRated safe working load
500 kgStatic test load applied
10 minLoad hold time
Fabric Damage✓ None
Seam Damage✓ None
Handle/Strap Damage✓ None
Permanent Deformation✓ None
Function Test✓ Passed
Verdict✓ Meets SWL

Laboratory-Verified Fabric Performance

Property Standard Requirement Measured (avg.) Result
Weight — 200 g/m² ±10% 205.4 g/m² ✓ Pass
Tensile Strength (Warp) TS EN ISO 1421 ≥ 670 N/5cm 796.0 N ✓ Pass
Tensile Strength (Weft) TS EN ISO 1421 ≥ 700 N/5cm 874.4 N ✓ Pass
Elongation at Break (Warp) TS EN ISO 1421 ≥ 30% 43.5% ✓ Pass
Elongation at Break (Weft) TS EN ISO 1421 ≥ 45% 62.8% ✓ Pass
Tear Strength (Warp) EN ISO 4674-1 ≥ 125 N 153.0 N ✓ Pass
Tear Strength (Weft) EN ISO 4674-1 ≥ 85 N 96.0 N ✓ Pass
Abrasion Resistance EN ISO 12947-2 / DIN EN 530 — No wear or holes at 50,000 cycles ✓ Pass
Colour Fastness to Rubbing (Wet/Dry) EN ISO 105-X12 ≥ 4/5 5/5 ✓ Pass
Light Fastness EN ISO 105-B02 ≥ 4 5 ✓ Pass
Flammability BS 7175 Crib 5 / DIN 4102-1 Meets criteria / B1 Meets criteria ✓ Pass
Antibacterial Activity — Meets acceptance criteria Meets criteria ✓ Pass
Cold-Flex Resistance (−20°C) DIN EN 1876-1 No cracking Passed ✓ Pass

Independent lab test report 100-2026-1, dated 07.03.2026, on the standard Navy Kodro fabric used across all sizes.

Certifications & Standards

🇪🇺 EU MDR 2017/745 — Class I📋 EN ISO 13485🔥 BS 7175 Crib 5 / DIN 4102-1 B1🧪 EN ISO 10993-1

Basic UDI-DI 8682550EVAC8W. Manufactured by Gentuğ Tekstil Ürünleri San. ve Tic. A.Ş., Savaş Cad. Söğüt Sok. No:1, 34173 Merter — İstanbul, Türkiye.

Where the EVAC Sheet Performs

✓ Acute Care Hospitals
✓ Ambulances & EMS
✓ Nursing & Care Homes
✓ Disaster Response
✓ Home Care
✓ Rehabilitation Centers
✓ Emergency Services
✓ Bariatric & Pressure-Risk Care

Indications & Contraindications

Indicated for patients who are:

Non-ambulatory · Semi-conscious or unconscious · Physically immobilized due to injury, illness or surgery · In need of emergency evacuation from a hospital, ambulance, home or disaster zone · At risk of pressure injuries and requiring frequent repositioning.

Not to be used for:

Vertical lifting via crane, hoist or pulley · Loads exceeding the 250 kg safe working load · Use on rough/abrasive surfaces · Use if visibly damaged, torn or with compromised stitching or handles · Long-term bedding — intended for short-term transfer only.

Frequently Asked Questions

What is the maximum weight the EVAC sheet supports?

The EVAC Patient Transfer Sheet has a rated Safe Working Load of 250 kg. An independent load test confirmed it withstands a static test load of 500 kg for 10 minutes with no fabric, seam, or handle damage — a 2x safety margin over the rated load.

Can the sheet be used for vertical lifting?

No. The sheet is designed and tested only for horizontal transfer or repositioning — it must never be used for suspension by crane, hoist or pulley.

How is the sheet cleaned and disinfected between patients?

It’s machine washable up to 90°C, or can be sprayed and wiped with a hospital-grade disinfectant (alcohol- or quaternary-ammonium-based) between patients. Air dry or tumble dry at max 40°C, and it’s compatible with steam sterilization (autoclave) under validated conditions.

How many people are needed to use it safely?

Typically 2-6 trained personnel, depending on the patient’s weight and condition, using all handles evenly to distribute the load. In an urgent evacuation, a single rescuer can pull the patient to safety using the foot-end handle.

How long can the sheet be stored and used?

If stored properly – cool, dry, away from direct sunlight, between 0C and +45C – the sheet can be used for at least 15 years provided it has not been deployed in an actual rescue situation. Regular function checks are recommended.

Request Technical Specifications

For detailed specifications, IFU documents and quotation, reach out to our technical sales team.

✉ Contact Gentuğ